一、summarize
DRP2 Modularization Terminal Combination Distribution Box is a kind of power distribution device developed by the company according to the market demand. The box is made of metal material folded and welded. The panel and door are made of flame-retardant material ABS. The box is equipped with insulation. Seats, grounding, zero terminals and top hat rails are provided with inlet and outlet holes at the bottom of the top and bottom.
二、scope of application
DRP2 Modularization Terminal Combination Distribution Box is suitable for the installation of module electrical components with a track width of 9mm with track card. The line principle is 380V/220v three-phase five-wire and single-phase three-wire control circuit. According to the needs of free combination, and made into home lighting boxes, electrical equipment control box.
From the luxury series of terminal distribution box, with a unique human form design, as the indoor lighting, sockets, electrical overload, over-voltage leakage short-circuit protection, applicable to all types of residential, high-rise building hotel building • Shopping malls, industrial and mining companies and other construction sites. Clearly and concealedly.
三、 product model and meaning
四、technical parameters
1. frequency withstand voltage: 2000v 1min;
2. grounding resistance: not more than 0,05:
3.the edge of the DC resistance: not less than 5M.
4.protection class 丨 P30;
五、Installation methods and conditions
1. install clear and concealed two kinds:
a. concealed: installed in a hollow wall;
b. surface mounted: installed on a non-flammable wall;
2. the temperature range during the installation: a 15 °C • +60 °C;
3. maximum temperature during the building process: +60 °C;
六、installation methods and protection
Open the small door and open the two screws on the left and right mounting panels of the door frame. Use a screwdriver to unscrew the screws and remove the panel and door. You can install electrical components and complete wiring. After the wiring is completed, tighten the screws on the cover.
When the electrical components are energized in the enclosure, it must be ensured that the enclosure is reliably grounded.
七、shape and installation size
Countdown number
|
Surface mounted
|
Concealed
|
thickness
|
A
|
B
|
A
|
B
|
C
|
8
|
250
|
230
|
230
|
210
|
90
|
12
|
319
|
250
|
301
|
228
|
90
|
16
|
391
|
250
|
373
|
228
|
90
|
20
|
463
|
250
|
443
|
220
|
90
|
Note: C includes the panel thickness.
八、ordering instructions
standard product
1.the customer provides a detailed system diagram;
2.the installation method (surface or concealed);
Non-standard products
1. No knock-down hole requirements;
2. The knock hole size proposed by the customer;
3. connection method;
4.Other special requirements.